Dark Light
-2%

Mecer Winner Pro ME-2000-WPRU Uninterruptible Power


• True double-conversion online UPS
• Wide input voltage range (110-300 VAC)
• Input power factor correction 0.99
• Output power factor 0.8
• Converter mode available
• ECO mode operation for energy saving (only available for 1-3KVA)
• Hot-swappable battery design only available for 1-3KVA
• Generator compatible
• Adjustable charging current via LCD or software (1A ~ 6A)

KSh 90,000.00 KSh 92,000.00

Mecer Winner Pro ME-2000-WPRU Uninterruptible Power

Specifications

MODELME-1000-WPRUME-2000-WPRUME-3000-WPRUME-6000-WPRUME-10000-WPRU
PHASESingle phase with ground
CAPACITY1000 VA / 800 W2000 VA / 1600 W3000 VA / 2400 W6000 VA / 4800 W10000 VA / 8000 VA
INPUT
 

 

Voltage Range

Low Line Transfer160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp.<35°C)

(based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)

176 VAC ± 3% @ 100% load

110 VAC ± 3% @ 50% load

Low Line Comeback175 VAC /155 VAC/ 135 VAC /125 VAC± 5 % (Ambient Temp.<35°C)

(based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)

186 VAC ± 3% @ 100% load

120 VAC ± 3% @ 50% load

High Line Transfer300 VAC ± 5 %300 VAC ± 3%
High Line Comeback290 VAC ± 5 %290 VAC ± 3%
Frequency Range40Hz ~ 70 Hz46~54 Hz or 56~64 Hz
Power Factor≧ 0.99 @ nominal voltage≧ 0.99 @ 100%load
OUTPUT
Output Voltage200/208/220/230/240 VAC208/220/230/240 VAC
AC Voltage Regulation

(Batt. Mode)

± 1%± 1%
Frequency Range

(Synchronized Range)

47 ~ 53 Hz or 57 ~ 63 Hz46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode)50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:13:1
 

Harmonic Distortion

≦ 3 % THD (Linear Load),

≦ 6% THD (non-linear load)

≦ 3 % THD (Linear Load)

≦ 5 % THD (Non-linear Load)

Transfer

Time

AC Mode to Batt. ModeZero
Inverter to Bypass4 ms (Typical)Zero
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
AC Mode88%89%90%92%93%
Battery Mode83%87%88%90%91%
BATTERY
Battery Type12 V / 9 Ah12 V / 9 Ah12 V / 9Ah12 V / 9 Ah12 V / 9 Ah
Numbers2461616
Typical Recharge Time4 hours recover to 90% capacity9 hours recover to 90% capacity
Charging Current (max.) 1.0 A1.0 A / 2.0 A (adjustable)
Charging Voltage27.4 VDC ± 1%54.7 VDC ± 1%82.1 VDC ±1%218.4 VDC ±1%218.4 VDC ±1%
INDICATORS
LCD PanelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
PHYSICAL
Dimension, D x W x H (mm)310 x 483 x 88 [2U]410 x 483 x 88 [2U]630 x 483 x 88 [2U]UPS: 530 x 483 x 88 [2U]

Battery: 668 x 438 x 88 [2U]

UPS: 580 x 483 x 133 [3U]

Battery: 588 x 438 x 133 [3U]

Net Weight (kgs)121929.3UPS: 15

Battery: 48

UPS: 18

Battery: 51

ENVIRONMENT
Humidity20-90 % RH @ 0- 40°C (non-condensing)0-95 % RH @ 0- 40°C (non-condensing)
Noise LevelLess than 50dB @ 1 MeterLess than 55dB @ 1 MeterLess than 58dB @ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/ 2008, Windows 7/8, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
SKU: OF2866 Category:

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Mecer Winner Pro ME-2000-WPRU Uninterruptible Power”

There are no reviews yet.