Giganet GN-UPS-2KVAS-RT 2kVA Smart Online UPS


  • True double-conversion

  • The rack-mounted and floor-standing tower can be convertible

  • Patented Mimic LCD of which content can be rotated according to the type of deployment

  • Digital control guarantees high reliability

  • Output receptacle control for non-critical load shedding capability

  • ECO mode operation for energy saving

  • Emergency power-off function(EPO)

  • Generator compatible

  • Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional)

  • The bypass can be used when UPS is off(Set in LCD)

  • Cold start

Giganet GN-UPS-2KVAS-RT 2kVA Smart Online UPS (Includes SNMP Card and Rails)

Features

Includes SNMP Card and Rails
Online Double Conversion
Wide Input Voltage Range (110~300 Vac)
Input Power Factor 1 ( With PFC)
Output Power Factor 1.0
Rack Mounted and floor standing tower can be converted
Maximum Charging Current 12A (Long Run Unit)
Charging Current can be set by LCD (Long Run Unit)
50Hz/60Hz Frequency Converter Mode
Emergency Power Off Function (EPO)
ECO Mode Opertation for Energy Saving
Generator Compatible
SMNP+USB+RS232 Multiple Commincations
Smart Charging Design for Optimal Performance
Support Lithium Battery and BMS

Specifications

ModelGN-UPS-1KVAS-RTGN-UPS-2KVAS-RTGN-UPS-3KVAS-RT
Capacity VA/Watts1000VA/1000W2000VA/2000W3000VA/3000W
PhaseSingle Phase With Ground
INPUT
Nominal Voltage200/208/220/230/240 Vac
 

 

 

 

 

Operating Voltage Range

Low Voltage of Transfering to Bypass160Vac ± 5%@100%-80% load 140Vac ± 5%@ 80%-70% load 120Vac ± 5%@70%-60% load 100Vac ± 5%@ 60%-0% load(Ambient Temp <35°C)
Low Threashold Voltage of Recov- ering from Bypass175Vac ± 5%@100%-80% load 155Vac ± 5%@ 80%-70% load 135Vac ± 5%@70%-60% load 125Vac ± 5%@ 60%-0% load(Ambient Temp <35°C)
High Voltage of Transfering to Bypass 

300Vac ± 5%

High Threashold Voltage of Recov- ering from Bypass 

290Vac ± 5%

Input Voltage Range55-150Vac or 110-300Vac@60% load. 80-15-45 Vac or 160-300Vac@100%
Operating Frequency Range40-70Hz
Power Factor1
Genarator InputSupport
OUTPUT
Output Voltage200/208/220/230/240Vac
Power Factor1.0
Voltage Regulation± 5%
 

 

Frequency

Line Mode (Synchronized Range) 

47-53Hz or 53-67Hz

Bat.Mode(50/60 ±0.1)Hz
Crest Factor3:1
 

Harmonic Distortion

≤2% THD (Linear Load)
≤2% THD (Non-Linear Load)
WaveformPure Sinewave
 

Transfer Time

Ac Mode <- > Bat.ModeZero
Inverter <-> Bypass4ms(Typically)

Efficiency

AC-Mode88%92%92%
Battery Mode85%88%90%
BATTERY
Battery Type12V9AHDepends on Capacity of External Batteries12V9AHDepends on Capacity of External Batteries12V9AHDepends on Capacity of External Batteries
Numbers223446668
Backup TimeDepends on Capacity of External Batteries
Typical Recharging Time (Standard Time)4 Hours Recover 90% Capacity
Charging Voltage24.7VDC ±

1%

24.7VDC ±

1%

41.1VDC

± 1%

54.7VDC ±

1%

54.7VDC ±

1%

82.1VDC ±

1%

82.1VDC ±

1%

82.1VDC ±

1%

109.4VDC

± 1%

Charging Current Max1A or 2A12A Max Can be Set on LCD1A or 2A12A Max Can be Set on LCD1A or 2A12A Max Can be Set on LCD
SYSTEM FEATURES
 

 

 

Line Mode Battery Mode

 

Ambient Temp

<35°C

105%-110% : UPS Transfer to Bypass after 10 Minutes When the utility is in Normal 110%-130% : UPS Transfer to Bypass after 1 Minute When the utility is in Normal 130%-150%: UPS Transfer to Bypass after 5 Seconds When the utility is in Normal

>150%: UPS Transfer to Bypass Immediately When the utility is in Normal

<35°C

Ambient Temp

<40°C

105%-110%: UPS Transfer to Bypass after 5 Minutes When the utility is in Normal 110%-130% : UPS Transfer to Bypass after 1 Minute When the utility is in Normal

>130% : UPS Transfer to Bypass after Immediately When the utility is in Normal

 