C-TEC CFP708-4 8 Zone Conventional Fire Alarm Panel


  • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
  • Manufactured by C-TEC in the UK.
  • Eight detector zone circuits.
  • Four conventional sounder circuits.
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
  • Two on-board relays (Fire and Fault).
  • Two open-collector outputs (Remote and Reset).
    ‘Class change’ and alert inputs.
  • Installer-friendly design.

C-TEC CFP708-4 8 Zone Conventional Fire Alarm Panel

The C-TEC CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price and is ideal for small to medium fire alarm systems in commercial or residential buildings.

Specification

Approvals/certificationsCertified to EN54-2/4 by the LPCB (176b) / (0832-CPD-1704).
Mains supply230V 50/60Hz.
Mains rated current350mA maximum.
Internal power supply19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to1.5A @ 230Vac (ImaxA eq 146mA).
Quiescent current25mA (mains failed, internal sounder active, PSU & gen fault LED lit).
Max battery size and type2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah.
No. of detector zone circuits8 (Max. length per circuit is 500m).
Call point resistor value470 to 680Ω.
Max. devices per detector zone25 detectors (or 32 detectors/manual call points combined).
No. of conventional sounder circuits4 (Max. length per circuit is 500m).
EOL resistor value6800Ω 5% Tol. 0/25W (blue, grey, red, gold).
Alarm voltage27V max, 20V min (final battery voltage).
Max. sounder output current4 x 200mA (800mA total).
Auxiliary relaysTwo: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.
Open collector outputsTwo: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit voltage 27Vdc)
Other outputs24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed).
Auxiliary inputsTwo: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching)
Engineer (AL3) functionsProgram coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters alarm; Enter fault diagnostic facilities
Expansion connectionsYes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards.
Product dimensions (mm)380 W x 235 H x D 96mm.
Construction & finishPlastic lid and base; RAL7035 textured.
IP RatingIP30.
Weight1.75kg (without batteries).
Operating conditions/temperature-5ºC to +40ºC. Max relative humidity: 95%.
Product dimensions:380 W x 235 H x 96 D mm.
Hole required for flush mounting:367 W x 220 H x 75 D mm. No bezel required.
SKU: OF3061 Category: